Coding of the auxiliary/additional heater control unit -J364

 

                        Code                                        Meaning

 

0                                                                      No assignment

       0                                                               No assignment

 

                                                                        Coolant shut-off valve -N279

 

 

            0                                                          No shut-off valve -N279 fitted.

                                                                        - Coding for vehicles with diesel engines without                                                                                     auxiliary heater optional extra

                                                                        - Possible coding of auxiliary/additional heater at                                                                                   customer request (if customer primarily requires

                                                                        auxiliary heater for heating of the engine).

 

            1                                                          Shut-off valve -N279 fitted.

                                                                        - Coding for vehicles with auxiliary/additional heater

 

                                                                        Circulation pump -V55

 

                        0                                              No circulation pump -V55 fitted.

                                                                        - Coding for vehicles with diesel engines without

                                                                        auxiliary heater optional extra

                       

                        1                                             Circulation pump -V55 fitted.

                                                                        - Coding for vehicles with auxiliary/additional heater

 

                                                                        Mode of low voltage shut-off

 

                                    1                                  Shut-off because of low voltage by the energy

                                                                        management control unit -J644.

                                                                        - Ex factory coding for vehicles with

                                                                        auxiliary heater optional extra (or auxiliary/additional

                                                                        heater).

 

                                    2                                  The low voltage shut-off occurs at the voltage entered in

                                                                        the Adaption function (fixed value).

                                                                        - Ex factory coding for vehicles with diesel engines

                                                                        without auxiliary heater optional extra

                                                                        - Possible coding of auxiliary/additional heater at

                                                                        customer request (if customer does not require

                                                                        low voltage shut-off by control unit -J644 in auxiliary

                                                                        heater operation).

 Notes:

 

Adaption of auxiliary/additional heater

Adaption channels provided

Adaption channel   Function
  01 

- Voltage value for low voltage shut-off with code "00XX2" of control unit -J364 (depending on coding of /additional heater control unit -J364)

- Adaption of code "00XX1" ineffective (the auxiliary/additional heater is shut off as necessary by the energy management control unit -J6

- Shut-off because of low voltage of additional heater occurs at a fixed preset voltage

- Effective with code "XXXX2".

- Setting ex factory 10.25 V

- Permissible adaption range 10.0 V to 11.0 V.

- Possible adaption range 9.5V to 12.5V

- Shut-off because of low voltage of auxiliary heater occurs at a fixed preset voltage.

- Effective with code "XXXX2" (can be done at request of customer, no shut-off of       energy management control unit -J644 desired).

- Setting higher than 11.30 V (at a lower setting engine starting problems may occur).

                                          

 

            02                                 Change of activation of combustion air blower

                                                -V6 to adjust the CO2 content in the exhaust gas.

                                                - Possible adaption range 100 to 255 V.

 

            03                                 Shut-off conditions of auxiliary heater after engine running.

                                                 

                                                - Adaption "1"

                                                When the engine is switched off the auxiliary heater is to

                                                continue running (until the preset operating time has elapsed).

                                                Factory setting.

                                                - Adaption "2"

                                                When the engine is switched off the auxiliary heater is to

                                                shut off automatically (regardless of the remaining

                                                operating time and even if there is still a

                                                switch-on signal in the data bus system -J285).

                                                This adaption can be performed at the request of the customer.

                                                 

 

            04                                 Adaption of a radio remote control to the auxiliary heater

                                                By way of this adaption channel up to 4 radio

                                                remote controls can be adapted to the auxiliary heater.

                                                - Readout = Send (the control unit -J364 sends the

                                                information: "Learn" to the radio receiver of the auxiliary

                                                heater -R64)

                                                - Readout = Learn (the auxiliary heater radio receiver -R64

                                                waits for a signal from the hand-held transmitter of the

                                                auxiliary heater radio remote control; press On button on radio

                                                remote control).

                                                - Readout = Learnt (the radio signal from the hand-held transmitter of the

                                                auxiliary heater radio remote control was detected and

                                                successfully learnt).

 

Adaption channel                                             Function

 

 

            05                                 Adaption channel currently not used

 

            06                                 Enable of "auxiliary heater" function in vehicles

                                                with petrol engines

                                                - In vehicles with diesel engine the auxiliary/additional

                                                heating is switched on as an auxiliary heater regardless of the adaption

                                                if the front operating and display unit

                                                -J255 of the air conditioner requested additional heating power over the

                                                data bus system.

                                                 

                                                - Adaption "0" (factory setting)

                                                In vehicles with petrol engine the auxiliary heater

                                                is not to be switched on as additional heating.

                                                - Adaption "1"

                                                This adaption can be performed at the request of the customer in

                                                vehicles with petrol engines.

                                                The auxiliary heater switched on as additional heating

                                                if the front operating and display unit

                                                -J255 of the air conditioner requested additional heating power over the

                                                data bus system.

                                                 

 

            07                                 Enable of an auxiliary/additional heater

                                                disabled because of faults in the combustion system

                                                - The auxiliary/additional heater is disabled if a

                                                fault occurs 3 times in succession in combustion mode.

                                                - Adaption "1"

                                                By entering adaption value "1" the disable

                                                is cancelled.

 

            10                                 Activation of recirculation pump -V55

                                                The recirculation pump -V55 is not fitted in vehicles with diesel

                                                engine without the "auxiliary heater" optional extra.

                                                 

                                                - Adaption "0" (input value "00000")

                                                Adaption in vehicles with additional heater (without

                                                "auxiliary heater" optional extra) ex factory.

                                                In auxiliary heating mode the recirculation pump -V55 is

                                                switched on at maximum delivery.

                                                The control unit -J364 does not switch the recirculation pump -V55

                                                on if a request is received over the data bus

                                                system.

                                                - Adaption "1" (input value "00001")

                                                The delivery rate of the recirculation pump-V55 is

                                                regulated in auxiliary heating mode. The control unit -J364 adjusts

                                                the delivery rate of the recirculation pump-V55 depending on

                                                the coolant temperature in the auxiliary heater (the -V55

                                                is pulsed).

                                                The control unit -J364 does not switch the recirculation pump -V55

                                                on if a request is received over the data bus

                                                system.

                                                - Adaption "2" (input value "00002")

                                                In auxiliary heating mode the recirculation pump -V55 is

                                                switched on at maximum delivery.

                                                The control unit -J364 switches the recirculation pump -V55

                                                on if a request is received over the data bus

                                                (to assist the coolant pump of the

                                                engine and the pump in the pump valve unit,

                                                thereby improving the coolant throughput through the heat exchangers

                                                of the AC unit and thus the heating power output).

 

Adaption channel                                             Function

 

 

            10                                 Activation of recirculation pump -V55 (continued)

                                                Adaption "3" (input value "00003")

                                                - Adaption in vehicles with an auxiliary/additional

                                                heater ex factory.

                                                - The delivery rate of the recirculation pump-V55 is

                                                regulated in auxiliary heating mode. The control unit -J364 adjusts

                                                the delivery rate of the recirculation pump -V55

                                                depending on the coolant temperature in the auxiliary heater

                                                (the -V55 is pulsed)

                                                - The control unit -J364 switches the recirculation pump -V55

                                                on if a request is received over the data bus

                                                 (to assist the coolant pump of the engine and

                                                the pump in the pump valve unit, thereby

                                                improving the coolant throughput through the heat exchangers

                                                of the AC unit and thus the heating power output).

 

            31                                 Adaption of the additional heater control unit -J364 to

                                                check the fuel delivery rate of the metering pump -V54

                                                - Adaption

                                                Setting for manufacturer "0"

                                                The metering pump -V54 is activated for the preset time (given

                                                in sec.) in the "basic setting, display group 077" function

                                                by the control unit -J364 at a preset frequency

                                                (e.g. in production to charge the fuel line).

                                                 

                                                To check the delivery rate of the metering pump -V54 the

                                                control unit -J364 is preset via the Adaption function to "250".

                                                 

                                                After in the "basic setting" function the display group

                                                "077" has been selected (e.g. to check the delivery rate of the

                                                metering pump -V54), the readout may change from e.g. "250"

                                                back to "0".

                                                In the case of a replacement control unit -J364 a

                                                value greater than "0" may be displayed. Change the adaption

                                                as necessary to "0".

Auxiliary/additional heater control unit -J364

 

Measured value block 001

Display zone 1

Instantaneous voltage of battery -A1 (terminal 30 in Volts).

- Measured by additional heater control unit -J364

Display zone 2

Current shut-off stages of energy management control unit -J644

J Readout: 0

- No request received to shut off the auxiliary/additional heater or to save energy

J Readout: Stage 1... 6

- Request received to shut off the auxiliary/additional heater or to save energy

(In auxiliary heating mode the auxiliary/additional heater is shut off in case of readout 4, 5 or 6)

 

Display zone 3

Value for shut-off of the auxiliary/additional heater because of low voltage (in Volts)

Auxiliary/additional heater (optional extra auxiliary heater, in vehicles with petrol of diesel engine)

With code 00XX1 (coding ex factory)

- The readout is irrelevant to operation of the auxiliary/additional heater; the auxiliary heater is shut off because of low voltage by a signal from the energy management control unit -J644 (see display zone 4)

J Readout: below 10.50 V

- If a voltage above 10.50 V is displayed, change the value by way of the Adaption function, adaption channel 01.

With code 00XX2 (coding on request of customer)

J Readout: above 11.30 V

- The voltage entered in the Adaption function for shut-off of the auxiliary/additional heater (above 11.30 V).

 

Additional heater (in vehicles with diesel engine, without the auxiliary heater optional extra)

With code 00XX2 (coding ex factory)

J Readout: below 10.50 V

- The voltage entered in the Adaption function for shut-off of the additional heater (10.0  V or above and below 11.0 V).

 

Display zone 4

Mode of low voltage shut-off.

J Readout: Automat (with code 00XX1)

- Coding ex factory with an auxiliary/additional heater

- Shut-off occurs as soon as a request is received from the energy management control unit -J644

J Readout: Manual (with code 00XX2)

- Coding ex factory with an additional heater, without the auxiliary heater optional extra

- Coding on request of customer with an auxiliary/additional heater

- A request to shut off because of low voltage from the energy management control unit -J644 is not met

- Shut-off because of low voltage occurs at the voltage displayed in display zone 3

(the low voltage shut-off occurs with a delay of approx. 20 seconds)

 

 

Measured value block 009

Display zone 1

The current burner operation of the auxiliary/additional heater was shut off by

J Readout: 00

- No shut-off is active

J Readout: 01... 09

- The auxiliary/additional heater was shut off by the control unit -J364 based on this request.

 

Display zone 2

The last burner operation of the auxiliary/additional heater was shut off by

J Readout: (see display zone 1)    

 

Display zone 3

The last-but-one burner operation of the auxiliary/additional heater was shut off by

J Readout: (see display zone 1)

 

Display zone 4

                                          

The last-but-two burner operation of the auxiliary/additional heater was shut off by

J Readout: (see display zone 1)

 

Shut-off conditions of the auxiliary/additional heater

- Code 01: Shut-off of the auxiliary/additional heater by a request received over the data bus system (crash signal, energy saving information, shut-off signal from radio remote control or from MMI, etc.)

- Code 02: Shut-off of the auxiliary/additional heater by a request transmitted by the VAS 5051 vehicle diagnostic, testing and information system, for example

- Display group number 033 was entered by way of the basic setting function, thereby shutting off the auxiliary heater switched on by the convenience system data bus, for example.

- Code 03: Shut-off of the auxiliary heater; the voltage applied to the input for activation of the auxiliary/additional heater for activation without the data bus was shut off.

- Input not assigned

- Input intended for auxiliary heaters fitted as optional extras and not activated via the data bus system.

- Code 04: Shut-off of the auxiliary heater by a switch-off signal received over the data bus system (auxiliary heater is switched off after engine has been running with switching off of engine). This shut-off function must be preset by way of the Adaption function.)

- Code 05: Shut-off of the additional heater by a switch-off signal received over the data bus system. (The engine was switched off; no more additional heating power is required to attain the preset interior temperature etc.)

- Code 06: Shut-off of the auxiliary/additional heater by a request received over the data bus system (there is insufficient fuel in the fuel tank.

The tank warning is active).

- Code 07: Shut-off of the auxiliary/additional heater by a request received over the data bus system (the preset on time has elapsed)

- Code 08: Shut-off of the auxiliary/additional heater because of a fault in the auxiliary/additional heater

(e.g. flame abort or no flame ignition)

- Code 09: Shut-off of the auxiliary/additional heater because of a fault in the auxiliary/additional heater

(e.g. in the combustion air blower -V6 or the metering pump -V54)

 

 

Integration of the auxiliary/additional heater in the vehicle electrics

a

 

 

A - 6-pin connector

B - 2-pin connector

C - Glow plug with flame monitor -Q8

D - Combustion air blower -V6

E - circulation pump -V55

F - Auxiliary/additional heater control unit J364

 

1...6 Contacts of the various connectors

 

 

Auxiliary/additional heater control unit -J364

 

Measured value block 001

 

Display zone 1

Instantaneous voltage of battery -A1 (terminal 30 in Volts).

- Measured by additional heater control unit -J364

 

Display zone 2

Current shut-off stages of energy management control unit -J644

J Readout: 0

- No request received to shut off the auxiliary/additional heater or to save energy

J Readout: Stage 1... 6

- Request received to shut off the auxiliary/additional heater or to save energy

(In auxiliary heating mode the auxiliary/additional heater is shut off in case of readout 4, 5 or 6)

 

Display zone 3

Value for shut-off of the auxiliary/additional heater because of low voltage (in Volts)

Auxiliary/additional heater (optional extra auxiliary heater, in vehicles with petrol of diesel engine)

 

With code 00XX1 (coding ex factory)

- The readout is irrelevant to operation of the auxiliary/additional heater; the auxiliary heater is shut off because of low voltage by a signal from the energy management control unit -J644 (see display zone 4)

J Readout: below 10.50 V

- If a voltage above 10.50 V is displayed, change the value by way of the Adaption function, adaption channel 01.

With code 00XX2 (coding on request of customer)

J Readout: above 11.30 V

- The voltage entered in the Adaption function for shut-off of the auxiliary/additional heater (above 11.30 V).

 

Additional heater (in vehicles with diesel engine, without the auxiliary heater optional extra)

With code 00XX2 (coding ex factory)

J Readout: below 10.50 V

- The voltage entered in the Adaption function for shut-off of the additional heater (10.0  V or above and below 11.0 V).

 

Display zone 4

Mode of low voltage shut-off.

J Readout: Automat (with code 00XX1)

- Coding ex factory with an auxiliary/additional heater

- Shut-off occurs as soon as a request is received from the energy management control unit -J644

J Readout: Manual (with code 00XX2)

- Coding ex factory with an additional heater, without the auxiliary heater optional extra

- Coding on request of customer with an auxiliary/additional heater

- A request to shut off because of low voltage from the energy management control unit -J644 is not met

- Shut-off because of low voltage occurs at the voltage displayed in display zone 3

(the low voltage shut-off occurs with a delay of approx. 20 seconds)

 

Measured value block 002

 

Display zone 1

Current coolant temperature in the auxiliary/additional heater in °C.

- Measured by a temperature sensor bolted onto the control unit -J364 in the auxiliary/additional heater

 

Display zone 2

Coolant temperature in °C received by the data bus system

- The temperature is delivered by the control unit in the dash panel insert or by the engine control unit.

- When the ignition is off no coolant temperature is received and a substitute value is applied,

e.g. -40 °C

 

Display zone 3

Current operating status of the auxiliary/additional heater

J Readout: off

- No switch-on signal received.

J Readout: Start, full throttle, partial throttle, control pause or run-on

- A switch-on signal is or was present; the auxiliary/additional heater is currently operating in this state

J Readout: Fault

- The control unit -J364 has detected a fault; the auxiliary/additional heater cannot be switched on or has been shut off

 

Display zone 4

Current operating mode of the auxiliary/additional heater

J Readout: off

- A signal to switch on auxiliary or additional heating has been received

- A signal to switch on the auxiliary/additional heater circulation pump -V55 has been received.

J Readout: Additional heater

- A switch-on signal is present; the auxiliary/additional heater is set to operate as an additional heater.

J Readout: Heating

- A switch-on signal is present; the auxiliary/additional heater is set to operate as an auxiliary heater.

J Readout: Pump on

- A switch-on signal is present and all switch-on conditions are met for the control unit -J364 to switch on the circulation pump -V55.

- This function is currently scheduled for all engine types in which the design of the coolant circuit requires the circulation pump -V55 to be switched on at low ambient temperatures in the lower engine speed range in order to improve the coolant flow through the air conditioner heat exchanger.

 

 

Measured value block 003

 

Display zone 1

Current coolant temperature in the auxiliary/additional heater in °C.

- Measured by a temperature sensor bolted onto the control unit -J364 in the auxiliary/additional heater

 

Display zone 2

Coolant temperature in °C received by the data bus system

- The temperature is delivered by the control unit in the dash panel insert or by the engine control unit.

- When the ignition is off no coolant temperature is received and a substitute value is applied,

e.g. -40 °C

 

Display zone 3

Activation of coolant shut-off valve -N279.

J Readout: 99 percent or 100 percent

- The shut-off valve is not activated (large coolant circuit; the coolant is drawn in by the auxiliary/additional heater via the engine).

J Readout: 1... 98 percent

- The shut-off valve is activated in loop control mode.

J Readout: 0 percent

- The shut-off valve is permanently activated (small coolant circuit; the coolant is drawn in by the auxiliary heater directly from the air conditioner unit heat exchangers).

 

Display zone 4

Activation of the combustion air blower -V6 in percent

J Readout: 0 percent

- The combustion air blower is not activated.

J Readout: 10... 100 percent

- The combustion air blower is activated in loop control mode.

 

Measured value block 004

Display zone 1

Current power factor for the glow plug (with flame monitor) -Q8

J Readout: 0 percent

- The glow plug is not activated.

J Readout: 50... 100 percent

- The glow plug is activated.

 

Display zone 2

Current power factor for the metering pump -V54

J Readout: 0 percent

- The metering pump is not activated.

J Readout: 20... 50 percent

- The metering pump is activated.

- At full throttle the metering pump -V54 is activated to approx. 45%

(corresponding to about 2 pulses per sec.)

- The -J364 control units currently fitted display only 50 percent in this display zone at maximum activation.

 

Display zone 3

Current power factor for the circulation pump -V55

J Readout: 0 percent

- The circulation pump is not activated.

J Readout: 10... 100 percent

- The circulation pump is activated in loop control mode.

- The on time is dependent on various conditions (operating mode of the auxiliary/additional heater, coolant temperature, adaption of the additional heater control unit -J364, etc.)

 

Display zone 4

Signal to activate the fresh air blower -V2

J Readout: off

- No request is sent to switch on the fresh air blower on the convenience system data bus

J Readout: on

- The request to switch on the fresh air blower is sent on the convenience system data bus

- The front operating and display unit -J255 switches the fresh air blower -V2 on

 

Measured value block 005

 

Display zone 1

Signal from flame monitor (fitted in glow plug -Q8)

J Readout: Detected

- The electrical resistance in the glow plug corresponds to a value which is set in burn mode.

- If Detected is shown and the exhaust gas emitted from the exhaust pipe of the auxiliary/additional heater is cold, this indicates a fault in the control unit -J364 of the auxiliary/additional heater.

J Readout: Not detected

- The auxiliary/additional heater is off

- The electrical resistance in the glow plug is outside the range in which the control unit

-J364 detects a flame

 

Display zone 2

Request for additional heater

- Only for vehicles with diesel engine

J Readout: 11111111

- The auxiliary/additional heater is switched on by the control unit -J364 as an additional heater

J Readout: XXXXXXXX

- The auxiliary/additional heater is not switched on as an additional heater by the control unit -J364 if there is a 0 at any position.

 

Shut-off conditions for additional heater

- Bit 0: No additional heating; there is a crash signal

- Bit 1: No additional heating; there is no request from the front operating and display unit -J255 (Econ mode)

- Bit 2: No additional heating; the engine is not running

- Bit 3: No additional heating; the auxiliary/additional heater is fitted in a vehicle with a petrol engine.

- In vehicles with petrol engines no additional heater is scheduled to be fitted

(Refer to the notes on the Adaption function in adaption channel 06)

- Bit 4: No additional heating; the auxiliary/additional heater is in control pause mode

(Based on the coolant temperature in the auxiliary/additional heater no more additional heating is required)

- Bit 5: No additional heating; the ignition is off (terminal 15)

- Bit 6: No additional heating; there is insufficient fuel in the fuel tank

(tank warning active)

- Bit 7: No additional heating; the ambient temperature is/was above 7°C (and is still above 5°C)

 

Display zone 3

The quantity of fuel consumed since the auxiliary/additional heater was switched on in cm3 (millilitres)

J Readout: 0... XXXXX ml

- The quantity of fuel is calculated by the control unit -J364 by activating the metering pump -V54 (approx. 0.06 cm3 per stroke of the metering pump).

- The value is sent by the control unit -J364 on the data bus system

(to calculate the fuel consumption of the vehicle).

 

Display zone 4

Ambient temperature -G17 in °C received from data bus system

- The temperature is displayed by the control unit in the dash panel insert

 

Measured value block 006

 

Display zone 1

Engine speed in rpm received from data bus system

 

Display zone 2

Activation of the auxiliary heater via an additional input

- Input not assigned

- Input intended for auxiliary heaters fitted as optional extras and not activated via the data bus.

                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               

Display zone 3

Current status of the signal from the auxiliary heater radio receiver -R64

- Only in conjunction with an auxiliary/additional heater

- The radio remote control should not be too close to the rear window when operated (if the radio signal is too strong reception problems may occur. As necessary, cover over the transmitter aerial with your hand or maintain a distance of at least 10 metres from the vehicle)

J Readout: Activated

- The control unit -J364 is ready to receive a radio signal; the auxiliary/additional heater can be switched on and off from the radio remote control.

J Readout: on

- A radio signal to switch on the auxiliary heating/ventilation is currently being received.

J Readout: off

- A radio signal to switch off the auxiliary heating/ventilation is currently being received.

J Readout: Deactivated, Transport or Blocked

- The auxiliary heating/ventilation cannot be switched on from the radio remote control at present.

- The Blocked readout appears, for example, in vehicles with a Telestart T90 type auxiliary heater radio receiver -R64 if a request to save energy is received from the control unit -J644 (see display group 001)

 

Display zone 4

Feedback for auxiliary heating/ventilation with radio remote control

- Only in conjunction with an auxiliary/additional heater with an auxiliary heater radio receiver -R64 (type

Telestart T90, phased introduction starting in Spring 2003). (In vehicles with a Telestart T70 type radio receiver no feedback information is sent to the hand-held transmitter)

J Readout: 11111

- The auxiliary heating/ventilation is switched on by the control unit -J364

(and a confirmation is sent via the vehicle aerial).

J Readout: XXXXX

- The auxiliary heating/ventilation is not switched on by the control unit -J364 if there is a 0 at any position.

 

Shut-off conditions for auxiliary heating/ventilation with radio remote control

- Bit 0: No auxiliary heating/ventilation; no request to save energy received (low voltage)

- Bit 1: No auxiliary heating/ventilation; there is insufficient fuel in the fuel tank (tank warning active)

- Bit 2: No auxiliary heating/ventilation; a fault is stored in the auxiliary/additional heater control unit -J364

- Bit 3: No auxiliary heating/ventilation; the auxiliary/additional heater control unit -J364 is in transport mode (ex factory setting to save energy until delivery to the customer)

- Bit 4: No auxiliary heating/ventilation; there is a crash signal present.

 

Measured value block 007

 

Display zone 1

Combustion duration of the auxiliary/additional heater in hours.

J Readout: 0... XXXXX

- The combustion duration of the auxiliary/additional heater is calculated by the control unit -J364

(at full and partial throttle)

 

Display zone 2

Operating time (on time) of the auxiliary/additional heater in hours.

J Readout: 0... XXXXX

- The operating time of the auxiliary/additional heater is calculated by the control unit -J364

(at full and partial throttle and in control pause mode)

 

Display zone 3

Number of glow cycles (starts) of the auxiliary/additional heater.

J Readout: 0... XXXXX

- The number of starts (glow cycles) of the auxiliary/additional heater is calculated by the control unit -J364.

- If no flame is produced on the first attempt at starting, and it is necessary to repeat the start, this is classified as an internal glow cycle (the readout is increased not by one but by two).

 

Display zone 4

Quantity of fuel combusted in the auxiliary/additional heater in litres.

J Readout: 0... XXXXX

- The quantity of fuel is calculated by the control unit -J364 by activating the metering pump -V54 (approx. 0.06 cm3 per stroke of the metering pump).

 

Measured value block 008

Display zone 1

Number of shut-offs of the auxiliary/additional heater because of excessive coolant temperature

J Readout: 0

- The auxiliary/additional heater was not shut off because of excessive coolant temperature since the last erasure of the fault memory.

J Readout: 1... X

- The auxiliary/additional heater was shut off X times because of excessive coolant temperature (above approx. 120 °C) (since the last erasure of the fault memory).

 

Display zone 2

Running time of the auxiliary/additional heater (including as additional heater) for this heating period since switch-on

J Readout: 0

- The auxiliary/additional heater is off

J Readout: 0... 3600 sec.

- The auxiliary heater was switched on so many seconds ago by the control unit -J364.

J Readout: 0... XXXX sec.

- The additional heater was switched on so many seconds ago by the control unit -J364.

(For additional heater operation no time limitation is planned).

 

Display zone 3

Remaining running time of the auxiliary/additional heater for this heating period until shut-off

- Only applicable to auxiliary heater operation; for additional heater operation no time limitation is planned.

J Readout: 0

- The auxiliary heater is off

J Readout: 3600... 0 sec.

- The auxiliary heater will be switched off in so many seconds by the control unit -J364.

 

Display zone 4

Request to activate the circulation pump -V55 to the control unit -J364

- To assist the engine coolant pump and the pump in the air conditioner pump/valve unit

J Readout: 1111111

- The control unit -J364 switches the circulation pump -V55 (of the auxiliary/additional heater on without activating the auxiliary heater)

J Readout: XXXXXXX

- The control unit -J364 does not switch the circulation pump -V55 on if there is a 0 at any position

- So the circulation pump does not have to be continually switched on and off, it remains on for at least 30 seconds, even if a request is only present for a few seconds, such as in the event of a quick throttle change.

 

Shut-off conditions for activation of the circulation pump -V55

- Bit 0: No additional activation; the engine speed is below 300 rpm or above 2000 rpm

- Bit 1: No additional activation; the ignition is off (terminal 15)

- Bit 2: No additional activation; no heating output is requested by the front air conditioner operating and display unit -J255 (Off mode is set, for example)

- Bit 3: No additional activation; the auxiliary/additional heater control unit -J364 is coded as an additional heater (without circulation pump -V55)

- Bit 4: No additional activation; the auxiliary heater is on and the circulation pump

-V55 is activated in auxiliary heating mode

- Bit 5: No additional activation; a fault is stored in the auxiliary/additional heater control unit -J364

- Bit 6: No additional activation; the ambient temperature is above 20°C

 

Measured value block 009

Display zone 1

The current burner operation of the auxiliary/additional heater was shut off by

J Readout: 00

- No shut-off is active

J Readout: 01... 09

- The auxiliary/additional heater was shut off by the control unit -J364 based on this request.

 

Display zone 2

The last burner operation of the auxiliary/additional heater was shut off by

J Readout: (see display zone 1)    

 

Display zone 3

The last-but-one burner operation of the auxiliary/additional heater was shut off by

J Readout: (see display zone 1)

 

Display zone 4

                             

The last-but-two burner operation of the auxiliary/additional heater was shut off by

J Readout: (see display zone 1)

 

Shut-off conditions of the auxiliary/additional heater

- Code 01: Shut-off of the auxiliary/additional heater by a request received over the data bus system (crash signal, energy saving information, shut-off signal from radio remote control or from MMI, etc.)

- Code 02: Shut-off of the auxiliary/additional heater by a request transmitted by the VAS 5051 vehicle diagnostic, testing and information system, for example

- Display group number 033 was entered by way of the basic setting function, thereby shutting off the auxiliary heater switched on by the convenience system data bus, for example.

- Code 03: Shut-off of the auxiliary heater; the voltage applied to the input for activation of the auxiliary/additional heater for activation without the data bus was shut off.

- Input not assigned

- Input intended for auxiliary heaters fitted as optional extras and not activated via the data bus system.

- Code 04: Shut-off of the auxiliary heater by a switch-off signal received over the data bus system (auxiliary heater is switched off after engine has been running with switching off of engine). This shut-off function must be preset by way of the Adaption function.)

- Code 05: Shut-off of the additional heater by a switch-off signal received over the data bus system. (The engine was switched off; no more additional heating power is required to attain the preset interior temperature etc.)

- Code 06: Shut-off of the auxiliary/additional heater by a request received over the data bus system (there is insufficient fuel in the fuel tank.

The tank warning is active).

- Code 07: Shut-off of the auxiliary/additional heater by a request received over the data bus system (the preset on time has elapsed)

- Code 08: Shut-off of the auxiliary/additional heater because of a fault in the auxiliary/additional heater

(e.g. flame abort or no flame ignition)

- Code 09: Shut-off of the auxiliary/additional heater because of a fault in the auxiliary/additional heater

(e.g. in the combustion air blower -V6 or the metering pump -V54)

                                                                                                                                                                           

Measured value block 010

 

Display zones 1 ... 4

Display zones currently not used

- Depending on the design version of the control unit, the readout from adaption channel 04 (wait, send, etc.) may appear in display zone 1

 

Measured value block 011

Display zone 1

Ambient temperature value in °C calculated by the front operating and display unit -J255 received from the data bus system

 

Display zone 2

Measured value in °C of ambient temperature sensor -G17 received from data bus system

 

Display zone 3

Measured value in °C of fresh air intake duct temperature sensor -G89 received from data bus system

- With the ignition off no measurement is received, and a substitute value, e.g. 77°C, may be displayed (depending on the design version of the control unit -J364)

 

Display zone 4

Display zone currently not used

 

Measured value block 012

Display zone 1

 

Fuel type received from the data bus system

- The displayed fuel type must match the readout in display group 014.

- In vehicles with petrol engines built at start of production (up to Spring 2003), depending on the design of the engine control unit the wrong fuel type may be transmitted. This causes no impairment of the auxiliary heating function in such vehicles.

J Readout: Eng.- Diesel (in vehicles with diesel engine)

J Readout: Eng.- Petrol (in vehicles with petrol engine)

 

Display zones 2 ... 4

 

Display zones currently not used

 

Measured value block 013

 

Display zone 1

Request to reduce the heating power output of the auxiliary/additional heater received from the data bus system

- Only relevant when auxiliary heater on

J Readout: off (no request is received)

J Readout: on (the front operating and display unit -J255 has calculated that no further full-load operation of the auxiliary heater is necessary to attain the specified interior temperatures)

 

Display zone 2

Request sent by the control unit -J364 onto the data bus system to activate the auxiliary heating icon in the dash panel insert clock

J Readout: off (no request is sent)

J Readout: on (the request to activate the icon is sent)

 

Display zone 3

Request sent by the control unit -J364 onto the data bus system to switch on the fresh air blower -V2 (to the front operating and display unit -J255)

J Readout: off (no request is sent)

J Readout: on (the request to switch on is sent)

 

Display zone 4               

Display zone currently not used

 

Measured value block 014

Display zone 1

 

Design of auxiliary/additional heater

- The displayed fuel type must match the readout in display group 12 (for exceptions see display group 12)

J Readout: CU.- Diesel (the auxiliary/additional heater is designed for diesel and the fitted control unit -J364 is configured accordingly)

J Readout: CU.- Petrol (the auxiliary/additional heater is designed for petrol and the fitted control unit -J364 is configured accordingly)

 

Display zones 2 ... 4

Display zones currently not used

 

Measured value block 015

 

Display zones 1 ... 4

 

Display zones currently not used

- Depending on the design version of the control unit, the software number of the additional heater control unit -J364 may be displayed in display zone 1.

 

 

Final control diagnosis

The following control elements of the additional heater control unit -J364, if fitted and coded, are activated one after the other:

I Circulation pump -V55

I Combustion air blower -V6

I Glow plug with flame monitor -Q8

I Metering pump -V54

I Signal for activation of fresh air blower

I Coolant shut-off valve, heating -N279

I Radio remote control connection


Menu

01- Engine Control Unit

02 - Transmission Control Unit

03 - Brake electronics

05 - Access / Start Auth

07 - MMI Head Unit

08 - Climatronic

09 - Central Electric 1

13 - Adaptive CC

15 - Airbag

16 - Steering Wheel

17 - Instrument Cluster

18 - Aux Heating

19 - Gateway

28 - Rear Climatronic

34 - Level Control

36 - Driver Seat memory

38 - Roof Electrics

3C - Lane Change

42 - Door Electronic Drivers

46 - Central Convenience

47 - Sound System

4F - Central Electronics 11

52 - Door Electric Passenger

53 - Parking Brake

55 - Headlight Control

61 - Energy Manager

62 - Door Elec RL

65 - Tyre Pressure

66 - Rear Seat

67 - Voice Control

77 - Telephone

 

 

 

18 - AUX Heat